首页  |  本刊简介  |  编委会  |  投稿须知  |  订阅与联系  |  微信  |  出版道德声明  |  Ei收录本刊数据  |  封面
长期侧流提取对EBPR系统除磷及其磷回收性能的影响
摘要点击 1796  全文点击 616  投稿时间:2018-02-05  修订日期:2018-03-20
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  强化生物除磷(EBPR)  厌氧上清液  侧流比  磷回收  长期
英文关键词  enhanced biological phosphorus removal (EBPR)  anaerobic supernatant  side stream ratio  phosphate recovery  long-term
作者单位E-mail
俞小军 兰州交通大学环境与市政工程学院, 兰州 730070 jorkyu@163.com 
李杰 兰州交通大学环境与市政工程学院, 兰州 730070  
周猛 兰州交通大学环境与市政工程学院, 兰州 730070  
宋璐 兰州交通大学环境与市政工程学院, 兰州 730070  
李维维 甘肃省轻工研究院, 兰州 730070  
王亚娥 兰州交通大学环境与市政工程学院, 兰州 730070  
马娟 兰州交通大学环境与市政工程学院, 兰州 730070
甘肃省污水处理行业技术中心, 兰州 730070 
meggyma@163.com 
吕慧 中山大学环境科学与工程学院, 广州 510006  
中文摘要
      实验采用交替厌氧/好氧(An/O)运行模式的SBR反应器,考察310 d内分3个批次提取侧流比为0、1/4、1/3、1/2的厌氧放磷上清液后EBPR系统的脱氮除磷效果及相应的磷回收性能.结果表明,整个实验阶段系统对COD和氨氮的去除较为稳定,出水均能满足《城镇污水处理厂污染物综合排放标准》一级A标准,总氮去除因厌氧阶段反硝化不断增强有所提升,达标率由88.2%显著上升至98.6%.然而,随着厌氧上清液提取次数的增多,系统释磷能力整体下降,但前两个批次中系统除磷均稳定高效,去除率在90%以上,相应地出水磷达标率大于75%,仅第3批次实验中侧流比为1/2时系统除磷率出现大幅波动,最低降为54.2%,并贡献该批次出水磷不达标率的60%,说明长期提取1/2侧流比不利于主流工艺出水稳定维持.研究还发现,长期进行侧流磷回收实验有利于污泥减量,且对污泥沉降性能影响不大.因此,在EBPR系统内长期提取适当侧流比的厌氧上清液以进行磷回收与主流工艺同步高效脱氮除磷具有可行性.
英文摘要
      A sequencing batch reactor (SBR) with alternating anaerobic/oxic (An/O) operation was employed to investigate nitrogen and phosphorus removal performance and corresponding phosphate recovery effect of an enhanced biological phosphorus removal (EBPR) system when extracting side stream ratios of 0, 1/4, 1/3, 1/2 anaerobic phosphorus supernatant. The operation involved three runs within 310 days. Removal efficiencies of COD and NH4+-N were found to be relatively stable over the entire experimental period and effluent could meet standard A of the national discharge standard of pollutants for municipal wastewater treatment plants. Total nitrogen removal improved due to enhancement of denitrification capability during the anaerobic phase, and the standard-reaching rate increased from 88.2% to 98.6%. Although phosphate releasing capability gradually decreased, phosphorus removal performances of the former two runs were stable and efficient. The removal rate was>90% and the corresponding standard-reaching rate was>75%. Nevertheless, phosphorus removal performance began to fluctuate with a side stream ratio of 1/2 during the third run. The lowest phosphorus removal rate was 54.2%, contributing to a 60% non-standard-reaching rate in this run. This suggests that long-term extraction of 1/2 side stream supernatant is not favorable for maintaining stable effluent of the main process. It was also found that long-term phosphate recovery through side stream extraction allowed reduction of sludge mass and had little impact on sludge settling performance. As a result, it is feasible to extract an appropriate side stream ratio of anaerobic supernatant to recover phosphate, combined with efficient removal of both nitrogen and phosphorus in the main process.

您是第53336637位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2