首页  |  本刊简介  |  编委会  |  投稿须知  |  订阅与联系  |  微信  |  出版道德声明  |  Ei收录本刊数据  |  封面
GC-MS和GC-ECD同时在线观测本底大气中的HCFC-142b
摘要点击 1707  全文点击 846  投稿时间:2012-08-23  修订日期:2012-09-24
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  气相色谱-质谱联用法(GC-MS)  气相色谱-电子捕获检测法(GC-ECD)  二氟一氯乙烷(HCFC-142b)  在线观测  本底大气
英文关键词  gas chromatography-mass spectrometry (GC-MS)  gas chromatograph-electron capture detector (GC-ECD)  HCFC-142b  in-situ measurement  background atmosphere
作者单位E-mail
郭立峰 黑龙江省气象科学研究所, 哈尔滨 150030
中国气象科学研究院,中国气象局大气化学重点开放实验室, 北京 100081 
kevin8257@163.com 
姚波 中国气象科学研究院,中国气象局大气化学重点开放实验室, 北京 100081  
周凌晞 中国气象科学研究院,中国气象局大气化学重点开放实验室, 北京 100081 zhoulx@cams.cma.gov.cn 
李培昌 中国气象科学研究院,中国气象局大气化学重点开放实验室, 北京 100081  
许林 中国气象科学研究院,中国气象局大气化学重点开放实验室, 北京 100081  
中文摘要
      2010年5月~2011年5月, 利用自组装气相色谱-质谱联用法(GC-MS)和气相色谱-电子捕获检测法(GC-ECD)在线观测系统, 在北京上甸子区域大气本底站开展了二氟一氯乙烷(HCFC-142b)在线观测对比实验, GC-MS和GC-ECD系统分析精度分别为0.23%和0.88%. 观测期间HCFC-142b浓度变化范围约为21×10-12~355×10-12; 通过独立样本T检验P>0.05, 表明两种方法获得的HCFC-142b浓度数据无显著性差异; 对两套系统观测浓度数据的差值分析表明, 造成两套系统观测浓度间微小差别的主要因素是空气样品时间分辨率和观测精度. 利用局部近似回归法进行本底值筛分, GC-MS和GC-ECD法获得的本底浓度均值差、中值差、25和75百分位数值差均优于系统观测精度. 两种方法捕获HCFC-142b污染过程一致, 污染浓度均具有夏秋高冬低的特点; 两种方法观测HCFC-142b污染浓度的年变化趋势一致.
英文摘要
      Custom-made GC-MS and GC-ECD in-situ measurement systems were established at the Shangdianzi GAW Regional station. From May 2010 to May 2011, the precisions for GC-MS and GC-ECD systems were 0.23% and 0.88%, respectively, and the HCFC-142b mole fraction during the observation period ranged from 21×10-12 to 355×10-12. The result of the independent-sample T test was P>0.05, and there was no significant difference in HCFC-142b mole fraction measured by the two systems. The small difference of HCFC-142b mole fraction measured by GC-MS and GC-ECD might be associated with the different sampling time and precision of the two systems. A statistical filter of "robust local regression" was applied to separate HCFC-142b background and pollution data. The mean difference, median difference, 25 and 75 percent difference of background data measured by GC-MS and GC-ECD were all within the precisions. The pollution events captured by the two systems showed similar characters. Results from both systems showed a higher HCFC-142b level in summer and autumn than in winter. The pollution mole fraction of the two systems showed similar seasonal changes.

您是第52892967位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2