首页  |  本刊简介  |  编委会  |  投稿须知  |  订阅与联系  |  微信  |  出版道德声明  |  Ei收录本刊数据  |  封面
不同消毒方式对饮用水生物活性炭出水消毒效果的对比研究
摘要点击 1976  全文点击 1675  投稿时间:2010-06-05  修订日期:2010-10-08
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  生物活性炭  次氯酸钠  氯胺  灭活率  卤代烃
英文关键词  biological activated carbon (BAC)  sodium hypochlorite  chloramine  disinfecting efficiency  halo hydrocarbon
作者单位
支兴华 上海交通大学生命科学技术学院水质科学与工程实验室上海200240 
白晓慧 上海交通大学生命科学技术学院水质科学与工程实验室上海200240 
孟明群 上海市供水调度监测中心上海200002 
中文摘要
      针对水厂生物活性炭深度处理工艺可能产生的细菌泄露问题,采用上海徐泾水厂生物活性炭出水,通过对异养菌平板计数和卤代烃气相色谱检测分析,比较了次氯酸钠和氯胺2种消毒方式对出厂水水质安全保障的效果.在水温30℃下,采用NaClO消毒剂进行消毒处理时,初始余氯值达到1.84 mg/L、 接触30 min即可保障灭活率lg(N0/n)超过2;若采用NH2Cl消毒,则初始余氯值为2.20 mg/L、 消毒接触90 min以上才可达到相同效果.采用NaClO消毒,初始余氯浓度1.53~2.42 mg/L时,CHCl3 和CCl4生成量分别为4.97~7.10 μg/L和0.01~0.71 μg/L;NH2Cl消毒,初始余氯2.10~2.86 mg/L时,CHCl3和CCl4生成量分别为4.43~5.55 μg/L和0.01~0.64 μg/L,生成的卤代烃含量低于国家生活饮用水卫生标准.本实验表明水中氯化消毒过程包括初始快速灭菌阶段与后期慢速灭菌阶段;针对水厂活性炭出水微生物含量较高现状,NaClO灭菌效果比NH2Cl好,但均难实现100%灭活,且在水温较高的条件下不会造成消毒副产物超标风险.
英文摘要
      Lab-scale tests were designed to treat the leak of bacteria from BAC process. Water samples from outlet of BAC pool in Xujing Waterworks in Shanghai were disinfected by NaClO and NH2Cl disinfectant to compare the disinfection efficiency. Heterotrophic bacteria in disinfected water were cultivated and counted and halo hydrocarbons were detected by GC. To keep the disinfecting efficacy [lg(N0/n)] over 2 under the water temperature of 30℃,NaClO should have an initial concentration more than 1.84 mg/L total chlorine and contact with bacteria for about 30 minutes. As to NH2Cl disinfection,the initial concentration should be more than 2.20 mg/L total chlorine and contacting time should be prolonged to about 90 minutes. The production of CHCl3 ranged from 4.97 to 7.10 μg/L and CCl4 ranged from 0.01 to 0.71 μg/L in NaClO disinfection tests with a initial disinfecting concentration in the range of 1.53-2.42 mg/L total chlorine values. In NH2Cl disinfecting tests,CHCl3 ranged from 4.43 to 5.55 μg/L and CCl4 ranged from 0.01 to 0.64 μg/L when initial disinfecting concentration limited in the range of 2.10-2.86 mg/L total chlorine values. All was below the state drinking water standard. The results showed that the disinfection process can be divided into fast step and slow step. NaClO has higher disinfecting efficiency on bacteria than NH2Cl,but neither can reach 100% effectivity. Meanwhile the risk of producing halo hydrocarbon over standard was proved to be negligible.

您是第53396950位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2