In the room temperature 14.7-24.7℃, simultaneous nitrification-ANAMMOX (CANON) process for municipal sewage was tested by SBR while the DO was controlled between 0.05 and 0.30 mg/L. As a result, the research shows that CANON process can be applied to the nitrogen treatment of municipal wastewater in room temperature by SBR. DO can be regarded as the indication parameter of reaction terminal, and 1 mg/L has been confirmed in the experiment. In the exploring SBR experiments, the consumption velocity of NH+4-N was 0.164-0.218 kg/(m3·d), the production velocity of NO-3-N was 0.026-0.036 kg/(m3·d),the removal velocity and efficiency of TN were 0.124-0.194 kg/(m3·d) and 65%-75% respectively. Additionally, in the improving SBR experiments, there were three methods for avoiding nitrite accumulation and increasing the nitrogen removal efficiency. They were improving temperature, adding non-aeration period of time and increasing the quantity of ANAMMOX bacteria.Therefore, the removal efficiency of TN was increased to 77%-88% through the three ways above. However, in view of the nitrogen removal velocity and the fact of engineering application condition, the third approach was the best to advance the general ability of ANAMMOX. |