生物膜对给水铸铁管腐蚀结垢的影响
摘要点击 2151  全文点击 1238  投稿时间:2008-02-29  修订日期:2008-06-24
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  铸铁管  生物膜  腐蚀  XRD  XPS
英文关键词  cast iron pipe  biofilm  corrosion  XRD  XPS
作者单位
滕飞 清华大学环境科学与工程系北京100084 
管运涛 清华大学环境科学与工程系北京100084 
李莎莎 北京科技大学土木与环境工程学院环境工程系北京100083 
祝万鹏 清华大学环境科学与工程系北京100084 
中文摘要
      采用XRD、XPS对给水铸铁管腐蚀结垢产物进行表征,结合水相中总铁浓度变化规律,研究了生物膜生长对给水铸铁管腐蚀结垢的影响.结果表明,0~7 d时生物膜存在条件下水相中总铁浓度更高,而15~30 d时无生物膜生长的对照组水相中总铁浓度更高.有生物膜生长时,锈垢的XRD图谱主峰为铁氧化物;无生物膜生长时,主峰为CaCO3,次峰为铁氧化物,表明生物膜的存在会影响锈垢中晶体的生长及组成.7 d时有生物膜生长组锈垢中铁的质量分数更高,而15 d和30 d时对照组锈垢中铁的质量分数更高.有生物膜生长组锈垢中钙的质量分数始终低于对照组,可能是胞外多聚物吸附或微生物生长消耗钙离子所致.上述结果表明,生物膜发育7 d时会促进铸铁管的腐蚀,而发育15~30 d时会抑制铸铁管的腐蚀;存在生物膜生长会对铸铁管锈垢的形态和组成产生重要影响.生物膜对腐蚀的抑制作用为控制配水管网管道的腐蚀提供了一条新的途径.
英文摘要
      The crystalline phase and the element composition in the scales on cast iron pipe for drinking water was identified with XRD and XPS respectively to investigate the effect of biofilm existence on the corrosion and fouling of cast iron pipe. The total iron concentration in the water phase was measured simultaneously. The results showed that on 0 -7 d the total iron concentration was higher in the water phase of the group with biofilm growth, but on 15-30 d it was higher in the water phase of the control without biofilm growth. The major peak of XRD patterns for the scales with biofilm growth was characterized as Fe oxide, while for the scales in the control it was always characterized as CaCO3. As presented by XPS atomic ratio, the Ca atomic percentage in the scales with biofilm growth was lower than that in the scales in the control, which might be contributed to the Ca2+ absorption by extracellular polymeric substances or Ca2+ consumption by microorganism growth. In comparison with that in the scales in the control, the iron atomic percentage in the scales with biofilm growth was higher on 7 d, while lower after 7 d. It can be concluded that on 0 -7 d the existence of biofilm could promote the corrosion of cast iron pipe while inhibit corrosion after 7 d. The variance of major peak of XRD pattern and XPS atomic ratio indicated that biofilm had important effect on the configuration and composition of the scales of cast iron pipe. The corrosion inhibition of biofilm thus provided a new pathway to control the corrosion of metal pipes in drinking water distribution system.

您是第52959241位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2