首页  |  本刊简介  |  编委会  |  投稿须知  |  订阅与联系  |  微信  |  出版道德声明  |  Ei收录本刊数据  |  封面
中国西部本底大气中CO的连续测量
摘要点击 1816  全文点击 1486  投稿时间:2000-07-06  
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  CO  本底浓度  气相色谱  汞置换法
英文关键词  carbon monoxide  baseline concentration  gas chromatography  mercury detection
作者单位
周凌晞 北京大学环境科学中心,北京100871 
汤洁 中国气象科学研究院
北京100081 
M.Ernst Atmospheric Environment Service,Toronto
Canada
Atmospheric Environment Service,Toronto
Canada 
D.Worthy Atmospheric Environment Service,Toronto
Canada
Atmospheric Environment Service,Toronto
Canada 
中文摘要
      在中国西北部的瓦里关全球基准站(36°17'N,100°54'E,3810m asl)建立了气相色谱-汞置换法大气CO连续测量系统.组装调试和运行标定表明,色谱方法的基线稳定,分离度高,检测方法可靠,系统具有高自动化的操作性能和严格的质量控制,其设计完全符合世界气象组织(WMO)全球大气本底测量的要求.根据采样现场大气CO浓度的变化,采用经国际比对的CO标准气系列,用峰高外标法设定可调整的标准工作曲线计算环境CO浓度,系统对CO的检测限低至1×10-9(V/V),检测精度小于0.1%,准确度在±0.05%以内,可提供我国本底地区近地层大气CO连续而精确的现场测量结果.
英文摘要
      In-situ custom-designed gas chromatography(GC)-HgO system was established for the continuous measurement of atmospheric CO at Waliguan Baseline Station(36°17'N,100°54'E,3816m asl) in western China. The system's assembling, testing, running and calibration indicated that the chromatographic method has stable baseline and high separation efficiency, as well as reliable detection method. This system adopted high automatic operating techniques and followed strict quality control. It is up to the standard of WMO's baseline watch on global atmosphere. According to the flask sampling results of in-situ CO variation at Waliguan, CO standards in clean dry air under international comparison were used to determine the adjustable working standard curves, so as to calculate the ambient CO mixing ratios based on peak height. This system's detection limit for CO is around 1×10-9(V/V),the precision is below 0.1% and accuracy in ±0.05%, it can provide continuous and accurate surface CO mixing ratios in baseline areas of China.

您是第53310486位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2