中文摘要 |
采用流动注射,离子交换与原子吸收联用技术,建立了天然水中铜、铅、镉和锰等重金属离子的在线预浓集火焰原子吸收分析方法。该方法具有快速、在线、微量、自动、密闭等优点,分析作频率为45/h,浓集倍数约20倍,相对标准偏差约为2.0%,适用于天然水中这些痕量离子的日常监测。文中讨论了各种实验条件对浓集效率的影响及其参数的选定。 |
英文摘要 |
The title method was developed,and some practical considerations in the design of on-line colunm preconcentration FIA system for FAAS were studied. The relative standard deviation was about 2.0% (n=11) at a sampling frequency of 45h-1 with an enrichment of around 20 times.The advantages,such as high-efficiency,on-line.accuracy,precision,micro-amount of sainble,automation et al.,made it possible to be applied to the routine analysis of natural waters. |
|
|
|