同轴流光电晕放电消除硫化氢试验研究 |
摘要点击 1349 全文点击 1354 投稿时间:1994-03-01 |
查看HTML全文
查看全文 查看/发表评论 下载PDF阅读器 |
中文关键词 脉冲流光电晕放电 H2S 消除率 能量利用率 废气处理 |
英文关键词 coaxial streamer corona H2S removal efficiency power utilization efficiency |
|
中文摘要 |
利用脉冲流光电晕放电消除臭气硫化氢H2S.对负脉冲供电、正脉冲供电和直流供电情况下,H2S消除效率及能量利用率进行了比较。结果表明脉冲流光电晕放电消除H2S是有效的。在负脉冲流光电晕放电过程中,H2S消除效率可达88%,能量利用率为6.74g(kW·h)。与负脉冲供电相同工作条件下,正脉冲流光电晕放电过程H2H消除效率为45%,能量利用率为2.27g(kw·h)。 |
英文摘要 |
The pulsed streamer corona have been used to remove odor(H2S).The H2S removal efficiency and power utilization efficiency were compared in the cases of negatively pulsed voltage,positively pulsed voltage and DC voltage. The results show that the pulsed streamer corona is effective to remove H2S.The negatively pulsed streamer corona was found to have a H2S removal efficiency of 88% and a power utilization efficiency of 6.749/(kw·h).In the same operating condition with negatively pulsed streamer corona,the positively streamer corona was found to have a H2S removal efficiency of 45% and a power utilization efficiency of 2.27g/(kw·h). |