首页  |  本刊简介  |  编委会  |  投稿须知  |  订阅与联系  |  微信  |  出版道德声明  |  Ei收录本刊数据  |  封面
水解(酸化)-缺氧-好氧固定床生物膜系统处理焦化废水的试验研究
摘要点击 751  全文点击 1105  投稿时间:1993-12-26  
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  水解-缺氧-好氧  固定床生物膜  焦化废水  活性污泥  弹性立体填料
英文关键词  acid hydrolysis-anaerobic-aerobic treatment system  fixed bed bio film  wastewater  from coking plant
作者单位
邵林广  
陈斌  
黄霞  
钱易  
中文摘要
      用内填YDT弹性立体填料的水解(酸化)-缺氧-好氧固定床生物膜系统处理焦化废水。结果表明:当进水COD和NH3-N浓度分别为1065mg/L和253mg/L,系统水力停留时间(HRT)为33.5h,混合液回流比为3.6时,出水COD约为180mg/L,NH3-N为5mg/L,COD和NH3-N的去除率分别达83%和98%。
英文摘要
      An acid hydrolysis- anaerobic-aerobic fixed biofilm system filled with a YDT elasto-steric pocking was used to treat wastewater from coking plant. The results show that when the system was operated with an influent in which the concentrations of COD and NH3-N were 1065 mg/L and 253 mg/L respectively, a total hydraulic residence time (HRT) of 33.5 h, and a mixed liquor recirculating ratio of 3.6, then there was an effluent with a COD concentration of about 180 mg/L and a NH3-N concentration of 5 mg/L, namely that the removals of COD and NH3-N were up to 83% and 98%, respectively.

您是第53178447位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2