铬对厌氧生物处理过程的抑制作用 |
摘要点击 1929 全文点击 1555 |
查看HTML全文
查看全文 查看/发表评论 下载PDF阅读器 |
中文关键词 厌氧生物处理 铬 抑制作用 |
英文关键词 anaerobic inhibition chromium |
|
中文摘要 |
本文研究了重金属铬离子(Cr3+和Cr6+)对厌氧生物处理过程抑制作用的规律.结果表明,Cr3+日引入量分别在低于20mg/L,36—109mg/L和高于145mg/L时,厌氧体系分别受到轻度、中度和重度抑制(即引起产气率下降分别为低于20%、20—40%和大于40%);日引入Cr6+浓度小于14mg/L,无抑制作用;36mg/L或高于70mg/L时,厌氧体系分别受到中度或重度抑制.单位污泥干重所允许承受Cr3+和Cr6+日引入量分别为低于0.1%(62.6 mg-N/kg)和0.04%(44.4mg-N/kg).在引入Cr3+的情况下,维持厌氧体系正常运行的溶解态铬离子浓度应小于0.5mg/L,超过2.5mg/L时,体系受到重度抑制;在引入Cr6+的情况下,允许浓度为 0.4 mg/L,超过2.8 mg/L为重度抑制. |
英文摘要 |
The inhibition of Chromium ion to anaerobic diges-non process was studied. The major toxicity to the anaerobic system was caused by the dissolved Chromium ion in the digestion system. When the daily addition dosage of Cr3+ to the digestion system was less than 20mg/L, betweeu 36-109mg/L and higher than 141mg/L. gas production would be reduced by less than 20%, 20-40% or higer than 40%, corresponding to light, significant, and serious inhibition effects, respectively. There was no inhibition observed when the daily addition dosage of Cr6+ was less than 14mg/L, while the daily addition of Cr6+ was roached to 36mg/L and more than 70mg/L, the inhibition effects were sign ficant and serious, respectively. When the percentages of daily addition amount of Cr3+ and Cr6+ in active sludge (dry weight) were less than 0.1% and 0.04%, it did not show any effec: on the digestion process. In order to keep good running of the anaerobic digestion system, the concentration of dissolved Cr3+ in digestion solution shuld be less than 0.5mg/L. When the concentration of Cr3+ was more than 2.5mg/L, the inhibition effect was serious, while for Cr6+, the corresponding levels were 0.4mg/L and 2.8mg/L, respectively. |
|
|
|