低成本单室微生物燃料电池型BOD传感器的研制
摘要点击 2761  全文点击 1673  投稿时间:2008-11-14  修订日期:2009-03-17
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  生化需氧量  微生物燃料电池  BOD传感器  标准曲线
英文关键词  biochemical oxygen demand(BOD)  microbial fuel cell  BOD sensor  standard curve
作者单位
吴锋 湖南农业大学生物科学与技术学院长沙410128 
刘志 湖南农业大学生物科学与技术学院长沙410128 
周顺桂 广东省生态环境与土壤研究所广州510650 
王跃强 广东省生态环境与土壤研究所广州510650 
黄赛花 广东省生态环境与土壤研究所广州510650 
中文摘要
      生化需氧量(biochemical oxygen demand, BOD)是表征有机物污染程度的综合性指标,传统的检测方法为5 d 20℃培养法,费时费力,不宜现场实时监测.以MnO2代替金属铂作阴极催化剂、以阳离子交换膜代替昂贵的质子交换膜,构建单室微生物燃料电池(microbial fuel cell)型BOD传感器,考察外接电阻、阳极液pH值、检测时间和清洗时间对检测效果的影响,并用该传感器检测实际水样BOD值,与传统BOD5值进行比较.结果表明:①以廉价MnO2为阴极催化剂,阳离子交换膜为隔膜,构建的单室MFC型BOD传感器成本低,结构简单,操作方便,可用于BOD的在线检测;②该BOD传感器的适宜运行条件为样品pH 7.0,外接电阻12 kΩ,检测时间2 h,清洗时间2~10 min;③实际水样检测结果显示,传感器最低检出限为0.2 mg/L,测量线性范围为BOD浓度5~50 mg/L,最佳测定范围为BOD浓度20~40 mg/L,精确度为0.33%,标准曲线线性相关系数达0.999 2,与BOD5比较,相对误差在4.0%以内.
英文摘要
      The 5-d biochemical oxygen demand (BOD5) test is the most conventional method to determine the concentration of biodegradable organics in wastewater. However, this method is time-consuming and usually requires experience and skill to produce creditable results, which is also not suitable for on-line measurements. This study described a single-chamber mediator-less microbial fuel cell (MFC)-type BOD sensor as an alternative method to BOD5. In such MFC, MnO2 was used as the cathode catalyst instead of Pt and the expensive proton exchange membrane was replaced with the cation exchange membrane. The factors including the external resistance, pH of anolyte, the reaction time and rinse time on BOD sensor were explored, and the results were compared with the values determined by BOD5. The experimental results showed that the optimal conditions are: the external resistance of 12 kΩ, pH of 7.0, and the reaction period of 2 h and the rinse time of 2-10 min. The low detection limit is 0.2 mg/L and the precision is 0.33%. This study indicates that MFC-type sensor can be used as a reliable method to determine BOD in wastewater, supported by the good linear correlation between BOD concentration and coulombs generation (regression coefficient, R2=0.999 2) and the small relative error of 4% between MFC-type sensor and BOD5. Such device provides a low-cost, easy-operated, fast-response, sensitive and reliable method to measure BOD in wastewater, and also is suitable for on-line measurements.

您是第76112418位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2