首页  |  本刊简介  |  编委会  |  投稿须知  |  订阅与联系  |  微信  |  出版道德声明  |  Ei收录本刊数据  |  封面
超声辐照-活性污泥联合处理焦化废水
摘要点击 2080  全文点击 2185  投稿时间:2002-05-31  修订日期:2002-07-12
查看HTML全文 查看全文  查看/发表评论  下载PDF阅读器
中文关键词  焦化废水  超声辐照  水质模型  活性污泥法
英文关键词  carbonization effluent  ultrasonic radiation  water quality model  activated sludge process
DOI    10.13227/j.hjkx.20030313
作者单位
宁平 昆明理工大学环境科学与工程学院 昆明650093 
徐金球 昆明理工大学环境科学与工程学院 昆明650093 
黄东宾 昆明理工大学环境科学与工程学院 昆明650093 
马晓利 昆明理工大学环境科学与工程学院 昆明650093 
徐晓军 昆明理工大学环境科学与工程学院 昆明650093 
李子燕 昆明理工大学环境科学与工程学院 昆明650093 
中文摘要
      选取昆明焦化制气厂的实际焦化废水为处理对象,用水质模型对超声辐照-活性污泥法处理焦化废水中有机物的降解进行了研究.实验结果表明,焦化废水初始浓度、曝气方式和声能密度对焦化废水中CODCr的降解效果影响显著.对初始浓度为807mg/L的实际焦化废水,选择空气作为曝气气体,向废水中曝气而不超声时,废水中CODCr降解率仅为4.5%;在声能强度为119.4kW/m2条件下,超声时其降解率可达65%;采用超声辐照-活性污泥法联合处理焦化废水CODCr,与单独采用活性污泥法相比,废水的CODCr降解率可由单独采用活性污泥法的45%提高至81%;经超声波预处理后的废水,加活性污泥后,其耗氧速率有明显的降低,说明经超声波预处理后的焦化废水对生物无毒性.
英文摘要
      The paper deals with the degradation of organic pollutants by the ultrasonic irradiation activated sludge process. The treatment of the real coking wastewater of Kunming coke making gas plant was studied with the water quality model. Using the ultrasonic irradiation activated sludge process the organic pollutants in the real coking wastewater can be degraded effectively. The influence factors of the ultrasonic degradation effect such as initial concentration, aerated gas and ultrasonic density were investigated and mechanism was explored. The result shows that the ultrasonic degradation effect was high with the decrease of initial concentration of the CODCr , the presence of aerated gas and the increase of ultrasonic density. At the initial CODCr concentration of 807mg/L, when air acted as aerated gas and only air itself (no ultrasound) was exerted on the wastewater, the degradation rate of the CODCr will be 4.5%. However, when the ultrasound of the intensity of 119.4kW/m2 was exerted on the wastewater, the degradation rate of the CODCr will be 65%. Compared with the activated sludge process alone, the combination of the ultrasonic irradiation and activated sludge process can increase the degradation rate of the CODCr from 45% to 81%. The oxygen consumption rate of the carbonization effluent obviously decreased in the presence of the activated sludge. This shows the carbonization effluent is not biotoxic behind the ultrasonic irradiation.

您是第83081639位访客
主办单位:中国科学院生态环境研究中心 单位地址:北京市海淀区双清路18号
电话:010-62941102 邮编:100085 E-mail: hjkx@rcees.ac.cn
本系统由北京勤云科技发展有限公司设计  京ICP备05002858号-2