中文摘要 |
在Triton X-100存在下,利用Ag+与Cadion的灵敏显色反应,建立了痕量氰化物的间接光度测定方法。该方法灵敏度高,选择性好,可用于废水中痕量氰化物的测定。测定范围为0-10μg/25ml,其相对标准偏差小于9.0%。 |
英文摘要 |
Silver gives a colour reaction with Cadion in the presence of Triton X-100, and suppression of the colour competitive complex ion of the silver can be used for the indirect spectrophotometric determination of trace cyanide.Cyanide in waste water can be separated by distillation from other ions that also interfere, and then determinated. The determination range of this method is 0-10 μg/25 ml. The recoveriesofstandard cyanide added to waste water samples are in the range of 91.0-100%, and its relative standard devistion is less than 9%. |