好氧条件下CANON工艺的启动研究 |
摘要点击 4883 全文点击 3358 投稿时间:2008-07-10 修订日期:2008-09-29 |
查看HTML全文
查看全文 查看/发表评论 下载PDF阅读器 |
中文关键词 部分亚硝化 ANAMMOX CANON 海绵 |
英文关键词 partial nitritatiom ANAMMOX CANON sponge |
|
中文摘要 |
为揭示厌氧氨氧化细菌对于DO的适应性及缩短CANON(completely autotrophic nitrogen removal over nitrite)工艺的启动时间,以海绵为填料,采用小试研究了CANON工艺直接在好氧条件下的启动启动过程中,控制温度在35%℃±1℃,pH 7.39~8.01 之司部分亚硝化在60 d得以建立,亚硝酸盐积累率(NO2--N/NOx-;-N)达到98%,并保持长期稳定;连续运行至160 d时,厌氧氨氧化作用开始逐步显现,到210 d时,TN去除负荷达到1.22 kg/(m3·d),TN去除率维持在约70%,成功地在好氧条件下启
动了CANON工艺启动过程中发现,以不含有机碳源的氨氮废水启动CANON反应器时,CANON反应器启动成功的标志为:①填料内部开始产气;②总氮损失与硝酸盐增加的比值趋于稳定,理论值为8,在本试验中,二者的比值平均为8.61 |
英文摘要 |
The start-up of CANON process was studied to reveal adaptability and how to condense time of start-up with a lab-scale experhnentDuring start-up stage,temperature was controlled at 35℃±1℃,pH was 7.39-8.01 and free ammonium was 2.89-12.37 mg·L-1.Partialnitritation was first built up in 60th day and kept steady,nitrite accumulation rate (NO2--N/NOx-N) was up to 98% In the 160th day,thereactor started to show effects of anaerobic ammonium oxidation,and in the 210th day,CANON process started-up under aerobic conditilossuccessfully,and total nitrogen removal load was 1.22 kg/(m3·d)and 70% removal rate on average was attained When using ammoniumwastewater without organic carbon sources as influent,there are two signs to indicate the CANON start-up:first,nitrogen gas was produced incarriers;the other one was the ratio of total nitrogen loss and increased nitrate keep steady,and in this study average ratio was 8.61 comparedto theoretical value 8. |