自来水厂污泥的流动电流特性 |
摘要点击 2120 全文点击 1307 投稿时间:2003-09-07 修订日期:2004-06-29 |
查看HTML全文
查看全文 查看/发表评论 下载PDF阅读器 |
中文关键词 水厂污泥 流动电流 沉降 脱水 调节机理 |
英文关键词 waterworks sludge streaming current settling behavior dewatering conditioning mechanisms |
|
中文摘要 |
以水厂混合污泥为对象,采用流动电流为特征参数分析加药量和pH对污泥沉降性能和脱水性能的影响,探讨流动电流技术在污泥处理中的适用性.结果表明,在污泥沉降性能方面,等电点处的投药量和pH值分别为8.9mg/L和7.25,实际最佳投药量和最佳pH为9.0mg/L和6.90.在污泥脱水方面,等电点处的投药量和pH值分别为25.0mg/L和9.25,实际最佳投药量和最佳pH为26.0mg/L和9.0.表明污泥调节的最佳投药量和最佳pH均处于流动电流值稍正的位置,可以用流动电流值作为单因子来控制污泥处理中的加药量,实现污泥加药的连续反馈控制.
|
英文摘要 |
The applicability of streaming current in waterworks sludge treatment as indicator of coagulant dosage and pH control was investigated in this study. Experiments were conducted on sludge settling behaviors and dewatering processes. At the aspect of sludge settleability research showed the theoretical optimal dosage, pH was 8.9mg/L, 7.25, and the practical optimal dosage, pH was 9.0mg/L, 6.90. On the side of sludge dewaterability, the theoretical optimal dosage, pH was 25.0mg/L, 9.25, and the practical optimal dosage, pH was 26.0mg/L, 9.0. Results indicated that slightly positive streaming current coincided with the optimal dosage and pH. Thus streaming current can be used for continuous dosage feedback control as the single indicator. |
|
|
|