焚烧法处理氯霉素生产废水 |
摘要点击 1431 全文点击 1976 投稿时间:1997-11-14 |
查看HTML全文
查看全文 查看/发表评论 下载PDF阅读器 |
中文关键词 氯霉素废水 焚烧法 还原-氧化二级物化法 废水处理 |
英文关键词 chloromycetin burning method reduced-oxidized method wastewater treatment |
|
中文摘要 |
采用焚烧法处理占氯霉素废水总量的60%、COD浓度为11.6×104mg·L-1的浓废水,被充分焚烧后的排气符合排放要求;对COD浓度为1.09×104mg·L-1的稀废水,自然稀释后浓度为500-1000mg·L-1,再经还原-氧化二级物化处理,其水质符合上海市工业废水排放标准。 |
英文摘要 |
Burning high concentration wastewater which makes up 60 per cent of the wastewater from producing chloromycetin with 11.6×104mg·L-1 COD was carried out in the test.Smoke and gas produced by efficiently burning waste water are accord with emission standard.It was found that the COD concentration of waste water reached 500—1000 mg·L-1 when low concentration influent with 1.09×104mg·L-1 COD was naturally diluted,then,the waste water was treated by two-step of reduced-oxidized physical-chemical method,the quality of effluent is in keeping with Shanghai emisson standard of industrial waste water. |